Add to Cart
Fire Resistant Aluminum Composite Panel For Building Material / Decoration
Fire Resistant Aluminum Composite Panels is one kind of the new decorative / building materials. made of by a fire resistant core with two layers of aluminum sheets. It is widely used in office buildings, shopping centers, industrial buildings, airports, hotels, bus stations, hospitals, schools, supermarkets, and residential buildings.
| Core Material | Normal PE | B1 | FR/HFR | A2 |
| FR Ingredients | 100% | <50% | <30% | <10% |
| Heat Value | >45 MJ/kg | <22 MJ/kg | <15 MJ/kg | <3 MJ/kg |
| Oxygen Index | 16-18 | 28-30 | 32-34 | ≥80 |
| FR Grade | CHN GB8624:B2 | CHN GB8624:B1 | CHN GB8624:B1-s1,d0,t0 EU EN13501:b-s1,d0 USA ASTME-84/NEPA285/ASTME-119 RU GOST30244-94/30402-96/12.1.044-89 UKR BV2.7-19-95(GOST30244-94) UK BS476Part6&7 GER DIN4102Part1 | CHN GB8624:A2-s1,d0,t0 EU EN13501:A2-s1,d0 SG PSB(BS476Part6&7):0,1 |
Physical Properties:
| No. | Item | Unit | Testing Method | Test Result |
| 1 | Density | G/cm3 | GB/T 1033 | 1.60 |
| 2 | Vicat Softening Point | ℃ | GB/T1633 | 86.2 |
| 3 | Melting Point | ℃ | G/T 1033 | 96 |
| 4 | Melt Index | Dg/min | GB/T3682185℃/2.18kg | 1.2~1.5 |
| No |
Test item |
Standard |
Standard index |
Text value |
Result | |
| 1 |
FIGRA ,W/S | GB/T 20284-2006 |
B | ≤120 | 10 |
eligible |
| 2 |
THR600s ,MJ | GB/T 20284-2006 | ≤7.5 | 1.9 | ||
| 3 |
LFS ,m | GB/T 20284-2006 |
<Sample side |
Pass | ||
| 4 |
Fs ,mm | GB/T 20284-2006 | ≤150 | 0 | ||
| 5 |
SMOGRA ,m2/s2 | GB/T 20284-2006 |
S1 | ≤30 | 1 |
eligible |
| 6 | TSP600S ,m2 | GB/T 20284-2006 | ≤50 | 33 | ||
| 7 | Drops after burning | GB/T 20284-2006 |
d0 |
600s no drops after burning |
Pass |
eligible |
| 8 | If filter paper catch fire | GB/T 8626-2007 |
Filter paper not catch fire |
Pass | ||
| 9 | Noxious fumes | GB/T 20284-2006 | t1 | ZA3 | ZA3 |
eligible |